englishdeutschfrançaischinese
Multi-function valve for dosing pumps

Four functions in one valve:
pressure loading, pressure relief, deaeration, drain

The new Grundfos Alldos multifunction valve is directly mounted on the discharge side of the dosing pump and disposes of two separate chambers controlled by diaphragms. Thus it can be used as both pressure loading valve for pressure build-up and pressure relief valve.
In case there is not enough backpressure in the system, the multifunction valve maintains the backpressure at the level which is necessary for the optimum functioning of the pump. On the other hand it protects the discharge side dosing line system from too high pressure build-up. The pump can be deaerated and the discharge side tubing system can be drained via the multifunction valve.

Easy commissioning:
Before starting the dosing pump operation, the dosing head is deaerated by opening the pres-sure relief valve.

High process quality:
If the backpressure which is necessary for an optimal functionality of the suction and pressure valves has been built up, the multi-function valve maintains the pressure constantly on the adjusted level. Optimal dosing is thus assured even in systems with pressure fluctuations or in depressurized systems.

High process reliability:
If the pressure exceeds the adjusted opening pressure, the multi-function valve opens and the dosing liquid can flow back into the dosing tank. The discharge side dosing line system is so protected from a too high pressure build-up.

Easy maintenance:
The entire pressure line can be drained by simply turning both handles of the multi-function valve.

Extra plus: the anti-siphon effect
The multi-function valve prevents unregulated flowing of the dosing liquid through the dosing lines (siphon effect), if the suction-side pressure is higher than or the same as the system pres-sure, but below the opening pressure of the multi-function valve.

Special highlight: free adjustment of the pressure ranges
The loading pressure is freely adjustable between 1 and 4 bar, the relief pressure between 7 and 18 bar.

Dosing pumps with Multi-function valve:
DMI 208 Etron with MFV
 
DMI 208 with MFV and Plus3 System
DME 8-12 with MFV
 
DDI Typ 209 with MFV
DDI Typ 209 with MFV, Plus3 System and Flow Monitor
 
DMX type 221 with MFV
DDI type 222 with MFV
   


 Connections
 Connection  DME  DMI  DMI
 P3
 DME  DDI  DDI
 P3
 DMX
 221
 DMH
 25x
 G 3/8"
 (DN 4)
 -  ≤6 l/h  -  -  ≤5,5 l/h  -  -  -
 G 5/8"
 (DN 8)
 -  ≤18 l/h  ≤5,2 l/h  -  ≤60 l/h  ≤4,9 l/h  ≤50 l/h  ≤50 l/h
 M 30  ≤12 l/h  -  -  ≤48 l/h  ≤60 l/h  -  -  -
 Werkstoffe
 Materials
 Valve body  Connections  Gaskets
 PVDF  PVC, PP or PVDF  EPDM or FKM