Compact measuring systems
for disinfection
For the convenient measurement and control of
 |
|
chlorine, |
 |
|
chlorine dioxide, |
 |
|
pH, |
 |
|
redox, |
 |
|
total chlorine or |
 |
|
chlorine independent from pH, |
 |
|
ozone, |
 |
|
hydrogen peroxide, |
 |
|
peracetic acid, |
 |
|
fluoride, |
we supply complete systems mounted on a plate and ready
for connection. This helps you to save valuable time and money.
Compact measuring systems with Conex :
Incl. measuring cell with hydromechanical cleaning:
Conex® DIA-1-A-D2 with Conex® DIA-1
Conex® DIA-2-A-D2
with Conex® DIA-2
Conex® DIA-2Q-A-D2 with Conex® DIA-2Q
 |
|
for chlorine, chlorine dioxide, ozone, optionally with pH compensation |
 |
|
incl. temperature sensor for temperature compensation |
 |
|
systems with Conex® DIA-2Q optionalyl with redox sensor |
 |
|
mounted on a base plate and wired |
 |
|
free adjustment of measuring
range:
0-50 mg/l chlorine, chlorine dioxide, 0 - 5 mg/l ozone |
Incl. pressure-proof measuring cell with hydromechanical
cleaning:
Conex® DIA-1-A-D3 with Conex® DIA-1
Conex® DIA-2-A-D3 with Conex® DIA-2
Conex® DIA-2Q-A-D3 with Conex® DIA-2Q
 |
|
for chlorine, chlorine dioxide, ozone, optionally with pH compensation |
 |
|
incl. temperature sensor for temperature compensation |
 |
|
incl. water sensor |
 |
|
systems with Conex® DIA-2Q optionalyl with redox sensor |
 |
|
mounted on a base plate and wired |
 |
|
free adjustment of measuring
range:
0-50 mg/l chlorine, chlorine dioxide, 0 - 5 mg/l ozone |
Incl. pressure-proof measuring cell with electric
cleaning motor:
Conex® DIA-1-A-D1 with Conex® DIA-1
Conex® DIA-2-A-D1 with Conex® DIA-2
Conex® DIA-2Q-A-D1 with Conex® DIA-2Q
 |
|
for chlorine, chlorine dioxide, ozone, optionally with pH compensation |
 |
|
incl. temperature sensor for temperature compensation |
 |
|
systems with Conex® DIA-2Q optionalyl with redox sensor |
 |
|
mounted on a base plate and wired |
 |
|
free adjustment of measuring range: 0-50 mg/l chlorine, chlorine dioxide, 0 - 5 mg/l ozone |
Additionally we offer compact measuring systems with Conex® DIA-1 for the following parameters:
 |
|
314-711: for acetic acid |
 |
|
314-811: for hydrogen peroxide |
 |
|
314-500: for fluoride |
 |
|
314-310: for total chlorine (with Conex® DIA-1, Conex® DIA-2 or Conex® DIA-2Q) |
 |
|
314-350: for free chlorine (with Conex® DIA-1, Conex® DIA-2 or Conex® DIA-2Q) |
Application of compact measuring systems with Conex :
 |
|
particularly in disinfection
and treatment of drinking water |
Compact Measuring Systems with DIP-A
-D2 Incl. measuring cell with hydromechanical cleaning:
 |
|
for chlorine, chlorine dioxide,
ozone, with pH- and temperature compensation |
 |
|
incl. temperature sensor for temperature compensation |
 |
|
mounted on a base plate and wired |
 |
|
free adjustment of measuring
range:
0-50 mg/l chlorine, chlorine dioxide, 0 - 5 mg/l ozone |
-D3 incl. pressure-proof measuring cell with hydromechanical cleaning:
 |
|
for chlorine, chlorine dioxide,
ozone, with pH- and temperature compensation |
 |
|
incl. temperature sensor for temperature compensation |
 |
|
incl. water sensor |
 |
|
mounted on a base plate and wired |
 |
|
free adjustment of measuring
range:
0-50 mg/l chlorine, chlorine dioxide, 0 - 5 mg/l ozone |
DIP-A-D1 inklincl. pressure-proof measuring cell with electromotorical cleaning:
 |
|
for chlorine, chlorine dioxide,
ozone, with pH- and temperature compensation |
 |
|
incl. temperature sensor for temperature compensation |
 |
|
mounted on a base plate and wired |
 |
|
free adjustment of measuring
range:
0-50 mg/l chlorine, chlorine dioxide, 0 - 5 mg/l ozone |
Applications of compact systems with DIP:
 |
|
particularly in disinfection
and treatment of swimming pool water |
|
|
Conex® DIA-1-A-D1
Conex® DIA-1-A-PR
Conex® DIS-A-PR-A
Conex® DIS-D-A-D2
DIP-A-D2
|