AquaCell
Modular potentiostatic combined measuring cells for disinfection
For chlorine, chlorine dioxide and ozone combined potentiostatic measuring
cells of type AquaCell have been developed, with an electric cleaning motor
or with hydromechanical electrode cleaning.
Applications:
Our sensors are specifically designed for water treatment and disinfection:
|
|
Drinking water
|
|
|
Swimming pool water
|
|
|
Industrial process and waste water
|
|
|
CIP applications
|
|
|
Bottle washing
|
The pressure-proof measuring cell types are employed,
wherever a lack of sample water cannot be tolerated:
|
|
Smaller swimming pools
|
|
|
Hotel pools
|
|
|
Therapeutical clinic pools
|
| Models |
Electrode cleaning |
Max. pressure |
Integrated equipment |
Parameters |
Measuring range |
| AQC-D1 |
motorical |
4 bar |
temperature sensor |
Cl2, ClO2
O3 |
0.05 - 50 mg/l 0.05 - 5.00 mg/l |
| AQC-D2 |
hydromechanical |
4 bar |
temperature sensor |
| AQC-D3 |
hydromechanical |
|
temperature sensor water sensor |
Features & Benefits:
|
|
Proven potentiostatic three-electrode measuring method directly in the sample water
|
|
|
Optimized electrode cleaning
|
|
|
Integrated filter cartridge and regulating device
|
|
|
Integrated temperature measurement
|
|
|
Special measuring chamber with calibration cup for pH single-rod probe and redox electrode
|
|
|
Very good flow characteristics
|
|
|
Easy to maintain construction
|
|
|
Nonwearing measuring and counter electrode
|
|
|
Easy exchange of the reference electrode
|
|
|
Conversion from hydromechanical to motorical cleaning is
possible at any time with a conversion set
|
|
|
AQC-D1
AQC-D2
AQC-D3
|
|