Sensitive and safe
Our measuring sensors are especially suited to water chemistry.
Applications:
|
|
Drinking water
|
|
|
Swimming pool water
|
|
|
Industrial process and waste water
|
|
|
Cooling water
|
|
|
CIP applications
|
|
|
Disinfection in bottling plants (beverages and liquid food)
|
|
|
Hotel pools and therapeutical clinic pools
|
| Parameter |
Sensor type |
Measuring range |
Admiss. pressure |
Admiss. temperature |
|
Single-rod probes: pH / Redox / Fluoride (F-)
|
| pH |
Ceramic diaphragm |
pH 0-12(14) |
0-6 bar |
-5 - +80 °C |
PTFE diaphragm |
pH 0-12(14) |
0-6 bar |
-5 - +80 °C |
KCl vessel connection |
pH 0-12(14) |
0-6 bar |
-5 - +80 °C |
Hole diaphragm |
pH 0-14 |
0-16 bar |
0-110 °C |
| Redox |
Ceramic diaphragm |
± 1500 mV |
0-6 bar |
-5 - +80 °C |
PTFE diaphragm |
| F- |
Monocrystal diaphr. |
0.00 - 2.00 mg/l |
|
0-50 °C |
|
Measuring cells: Peroxide (H2O2) / Peracetic acid (PAA) / Conductivity
|
| PAA |
Diaphragm covered |
0-2000 mg/l |
|
0-50 °C |
| H2O2 |
Diaphragm covered |
0-2000 mg/l |
|
0-45°C |
| Conductivity |
Conductive method |
0.05-20000 µS/cm |
max. 16 bar (25 °C) |
max. 135 °C (6 bar) |
Inductive method |
0.05-20000 µS/cm |
max. 6 bar (20 °C) |
max. 90 °C |
|
Gas sensors: Chlorine (Cl2) / Chlorine dioxide (ClO2) / Ozone (O3) /
Ammonia (NH3) / hydrochloric acid (HCl)
|
Cl2 lO2 O3 |
Amperometric probe (with Conex DIS-G and Conex DIA-G) |
0.00-5.00 ppm |
|
+5 - +45 °C |
| Cl2 |
Potentiostatic probe (only with Conex DIA-G) |
0.00-20.00 ppm |
|
-20 - +40 °C |
| ClO2 |
0.00-10.00 ppm |
| O3 |
0.00-10.00 ppm |
| NH3 |
0-100 ppm |
| HCl |
0.0-30.0 ppm |
|
|
Single rod probes
from the left to the right:
pH / Redox / fluoride
Conductivity probes:
left: conductive
right: inductive
Measuring Cell for
Peracetic acid or Peroxide
Gas sensors:
left: potentiostatic
right: amperometric
|