englishdeutschfrançaischinese

« previous product
next product »
Conex® DIA-2Q

Conex® DIA-2Q, the multifunctional measuring amplifier and controller
The Conex® DIA-2Q allows you to measure and control two parameter groups in parallel and to show these side by side on the display:

  Parameter 1: chlorine (Cl2), chlorine dioxide (ClO2), ozone (O3),
peroxide (H2O2), peracatique acid (PAA)
  Parameter 2: pH, redox or fluoride (F-)
Also integrated are compound loop control function and proportional mode function. Further Conex® DIA-2Q can measure the temperature of the water being disinfected.

Applications:
  Drinking water
  Swimming pool water
  Industrial water
  Waste water

Amplifier Conex® DIA-2Q
 Electronics  16 bit microprocessor system
 Display  high resolution plain-text LCD
 Enclosure  wall mounting (IP 65) or control panel installation (IP 54)
 Relay outputs  2 potential-free control relays
 (one for every of both parameters)adjustable as:
 - 2-position-controller (P / PI / PID): pulse-pause
 or pulse-frequency
 - set-point controller
 - proportional controller
 - compound loop controller
 Signal outputs  4 analogue signal outputs, galvanically
 separated from the inputs
 - 2 outputs for the parameters (1 for every of the two parameters)
 - 1 for the continous controller for parameter 1
 - 1 for the temperature or for the continous controller for parameter 2

Measuring parameters and ranges:
 Parameter 1  Parameter 2
 Cl2
 mg/l
 ClO2
 mg/l
 O3
 mg/l
 H2O2
 mg/l
 PAA
 mg/l
 pH  Redox
 mV
 F-
 0.00 -
 0.50
 0.00 -
 0.50
 0.00 -
 0.50
 0 -
 100
 0 -
 100
 0.00 -
 14.00
 ± 1500  0.00 -
 2.00
 0.00 -
 1.00
 0.00 -
 1.00
 0.00 -
 1.00
 0 -
 500
 0 -
 500
 2.00 -
 12.00
 0 -
 1000
 
 0.00 -
 2.00
 0.00 -
 2.00
 0.00 -
 2.00
 0 -
 1000
 0 -
 1000
 5.00 -
 9.00
   
 0.00 -
 5.00
 0.00 -
 5.00
 0.00 -
 5.00
 0 -
 2000
 0 -
 2000
      
 0.0 -
 10.0
 0.0 -
 10.0
              
 0.0 -
 20.0
 -               
 0.0 -
 50.0
 0.0 -
 50.0
           

Features & Benefits:
  Plain text menu and operator prompting: Everyone can use Conex® DIA-2Q and set process parameters with ease - even if they have little previous knowledge of the unit.
  Straightforward device calibration feature with plausibility check prevents errors occurring
  Multilingual menu: Simply change over to the language that you prefer
  Self-monitoring feature ensures excellent water quality at all times
  All disturbance variables are compensated means that chemical consumption is reduced to very low levels
 
Conex® DIA-2Q


More questions?
With pleasure we give answers to your questions and send you more detailed information leaflets. » To contact form